制备型高效液相色谱仪 Preparative HPLC
-
8/人使用者
-
38/次机时次数
-
205.53/小时总时长
-
0/次送样次数
-
27/人收藏者
-
收费标准
机时0元/小时 -
设备型号
Agilent 1260 Infinity II -
当前状态
-
管理员
文美玲 Wendy Meiling WEN,郑婷 020-88338595 -
放置地点
E4-126/133走廊-132
- 仪器信息
- 预约资源
- 附件下载
- 公告
- 同类仪器
名称
制备型高效液相色谱仪 Preparative HPLC
资产编号
BC-PM-0009
型号
Agilent 1260 Infinity II
规格
产地
厂家
Agilent Technologies
所属品牌
Agilent
出产日期
购买日期
所属单位
生物科学中央实验室 Biosciences Central Research Facility (GZ)
使用性质
科研
所属分类
BioCRF-蛋白质&代谢组学平台 Proteomics & Metabolomics Core
资产负责人
--
联系电话
020-88338595
联系邮箱
meilingwen@hkust-gz.edu.cn
放置地点
E4-126/133走廊-132
- 主要规格&技术指标
- 主要功能及特色
- 设备使用相关说明
主要规格&技术指标
G7157A Agilent 1260 Infinity II Preparative Autosampler
Weight: 19 kg (41.9 lbs) w/o sample thermostat
Dimensions (height × width × depth): 320 x 396 x 468 mm (12.8 x 15.6 x 18.4 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 350 VA / 350 W / 1195 BTU/h
Ambient operating temperature: 4 - 40 °C (39 - 104 °F), without sample cooler or sample thermostat up to 55 °C (131 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)1
Operating altitude: Up to 3000 m (9842 ft)
Non-operating altitude: Up to 4600 m (15092 ft)
Safety standards:IEC, EN, CSA, UL: Overvoltage category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B
Permitted solvents: Boiling point ≥56 °C (133 °F). Auto-ignition temperature ≥200 °C (392 °F)
G7161A Agilent 1260 Infinity II Preparative Binary Pump
Weight :27.2 kg
Dimensions (height × width × depth): 320 x 396 x 436 mm (12.6 x 15.6 x 17.2 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 350 VA, 320 W
Ambient operating temperature: 4 – 40 °C (39 – 104 °F)
Ambient non-operating Temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)
Operating altitude: Up to 3000 m (9842 ft)
Non-operating altitude: Up to 4600 m (15092 ft)
Safety standards:IEC, EN, CSA, UL: Installation category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B
G7114A Agilent 1260 Infinity II Variable Wavelength Detector
Weight: 11 kg (24.3 lbs)
Dimensions (height × width × depth): 140 x 396 x 436 mm (5.5 x 15.6 x 17.2 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 80 VA, 70 W
Ambient operating temperature: 4 - 55 °C (39 - 131 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)
Operating altitude: Up to 3000 m (9842 ft)
Safety standards:IEC, EN, CSA, UL: Overvoltage category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B
G1364E Agilent 1260 Infinity II Preparative Fraction Collector
Weight: 13.5 kg (29.8 lbs) w/o sample thermostat
Dimensions (height × width × depth): 200 x 345 × 440 mm (8 x 13.5 × 17 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 200 VA / 180 W
Ambient operating temperature: 4 – 40 °C (41 – 104 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 %, at 25 – 40 °C (77 – 104 °F)
Operating altitude: Up to 3000 m (9842 ft)
Safety standards:IEC, EN, CSA, UL: Overvoltage category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B
Permitted solvents: Boiling point ≥56 °C (133 °F). Auto-ignition temperature ≥200 °C(392 °F). Ignition Class IIA, IIB (IEC60079-20-1)
Weight: 19 kg (41.9 lbs) w/o sample thermostat
Dimensions (height × width × depth): 320 x 396 x 468 mm (12.8 x 15.6 x 18.4 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 350 VA / 350 W / 1195 BTU/h
Ambient operating temperature: 4 - 40 °C (39 - 104 °F), without sample cooler or sample thermostat up to 55 °C (131 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)1
Operating altitude: Up to 3000 m (9842 ft)
Non-operating altitude: Up to 4600 m (15092 ft)
Safety standards:IEC, EN, CSA, UL: Overvoltage category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B
Permitted solvents: Boiling point ≥56 °C (133 °F). Auto-ignition temperature ≥200 °C (392 °F)
G7161A Agilent 1260 Infinity II Preparative Binary Pump
Weight :27.2 kg
Dimensions (height × width × depth): 320 x 396 x 436 mm (12.6 x 15.6 x 17.2 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 350 VA, 320 W
Ambient operating temperature: 4 – 40 °C (39 – 104 °F)
Ambient non-operating Temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)
Operating altitude: Up to 3000 m (9842 ft)
Non-operating altitude: Up to 4600 m (15092 ft)
Safety standards:IEC, EN, CSA, UL: Installation category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B
G7114A Agilent 1260 Infinity II Variable Wavelength Detector
Weight: 11 kg (24.3 lbs)
Dimensions (height × width × depth): 140 x 396 x 436 mm (5.5 x 15.6 x 17.2 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 80 VA, 70 W
Ambient operating temperature: 4 - 55 °C (39 - 131 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 % r.h. at 40 °C (104 °F)
Operating altitude: Up to 3000 m (9842 ft)
Safety standards:IEC, EN, CSA, UL: Overvoltage category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B
G1364E Agilent 1260 Infinity II Preparative Fraction Collector
Weight: 13.5 kg (29.8 lbs) w/o sample thermostat
Dimensions (height × width × depth): 200 x 345 × 440 mm (8 x 13.5 × 17 inches)
Line voltage: 100 – 240 V~, ± 10 %
Line frequency: 50 or 60 Hz, ± 5 %
Power consumption: 200 VA / 180 W
Ambient operating temperature: 4 – 40 °C (41 – 104 °F)
Ambient non-operating temperature: -40 – 70 °C (-40 – 158 °F)
Humidity: < 95 %, at 25 – 40 °C (77 – 104 °F)
Operating altitude: Up to 3000 m (9842 ft)
Safety standards:IEC, EN, CSA, UL: Overvoltage category II, Pollution degree 2
ISM Classification: ISM Group 1 Class B
Permitted solvents: Boiling point ≥56 °C (133 °F). Auto-ignition temperature ≥200 °C(392 °F). Ignition Class IIA, IIB (IEC60079-20-1)
主要功能及特色
G7157A Agilent 1260 Infinity II Preparative Autosampler
Purification efficiency
• Needle flush port enables rinsing the outside of the needle for lowest carryover
• Low internal volume means minimum contribution to total internal volume of the system
Instrument efficiency
• Fully automated vial sampler for reliable injection of sample volumes from 0.1 μL to 3.6 mL
• Support of flow rates up to 200 mL/min at 400 bar
Laboratory efficiency
• Maximum capacity of 132 sample vials within the same foot print
• Flexible and convenient sample handling with different types of sample containers
G7161A Agilent 1260 Infinity II Preparative Binary Pump
Purification efficiency
• Outstanding retention time stability for routine operation Instrument efficiency
• Dynamic flow range up to 50 mL/min at 420 bar for semi-preparative applications
• Outstanding binary gradient compositional accuracy across a wide dynamic flow range
Laboratory efficiency
• Upper and lower pressure limits with automatic cutoff for increased safety in the event of column blockage or leakage
• Automated seal wash for extended seal lifetime
G7114A Agilent 1260 Infinity II Variable Wavelength Detector
Designed for highest optical performance, GLP compliance and easy maintenance with:
• higher data rate up to 120 Hz
• deuterium lamp for highest intensity and lowest detection limit over awavelength range of 190 to 600 nm
• optional flow-cell cartridges (standard 10 mm, 14 μL; high pressure 10 mm,14 μL; micro 3 mm, 2 μL; semi-micro 6 mm, 5 μL), Bio, and Prep Cells are available and can be used depending on the application needs
• Dual wavelength mode
• easy front access to lamp and flow cell for fast replacement,
• electronic identification of flow cell and lamp with RFID (Radio Frequency Identification) tag for unambiguous identification,
• lamp information: part number, serial number, production date, ignitions, burn time
• cell information: part number, serial number, production date, nominal path length, volume, maximum pressure
• built-in electronic temperature control (ETC) for improved baseline stability
• built-in holmium oxide filter for fast wavelength accuracy verification.
G1364E Agilent 1260 Infinity II Preparative Fraction Collector
Purification efficiency
• Lowest delay volumes for minimum peak dispersion and carryover
• Automated delay calibration facilitates highest fraction purity while maintaining high-precision sample recovery Instrument efficiency
• Per module collection of up to 216 fractions in glass tubes with 4 outer diameters of tubes available, or in microtiter plates
• Multiple collection modes with fraction triggering based on time, peak, or mass for exact collection of required fractions
Laboratory efficiency
• Expandable capacity up to 864 fractions within the same footprint
• Smooth upgrade paths allow you to increase capacity based on demand
• Forced fume extraction enables use of fraction collector outside a fume cupboard
Purification efficiency
• Needle flush port enables rinsing the outside of the needle for lowest carryover
• Low internal volume means minimum contribution to total internal volume of the system
Instrument efficiency
• Fully automated vial sampler for reliable injection of sample volumes from 0.1 μL to 3.6 mL
• Support of flow rates up to 200 mL/min at 400 bar
Laboratory efficiency
• Maximum capacity of 132 sample vials within the same foot print
• Flexible and convenient sample handling with different types of sample containers
G7161A Agilent 1260 Infinity II Preparative Binary Pump
Purification efficiency
• Outstanding retention time stability for routine operation Instrument efficiency
• Dynamic flow range up to 50 mL/min at 420 bar for semi-preparative applications
• Outstanding binary gradient compositional accuracy across a wide dynamic flow range
Laboratory efficiency
• Upper and lower pressure limits with automatic cutoff for increased safety in the event of column blockage or leakage
• Automated seal wash for extended seal lifetime
G7114A Agilent 1260 Infinity II Variable Wavelength Detector
Designed for highest optical performance, GLP compliance and easy maintenance with:
• higher data rate up to 120 Hz
• deuterium lamp for highest intensity and lowest detection limit over awavelength range of 190 to 600 nm
• optional flow-cell cartridges (standard 10 mm, 14 μL; high pressure 10 mm,14 μL; micro 3 mm, 2 μL; semi-micro 6 mm, 5 μL), Bio, and Prep Cells are available and can be used depending on the application needs
• Dual wavelength mode
• easy front access to lamp and flow cell for fast replacement,
• electronic identification of flow cell and lamp with RFID (Radio Frequency Identification) tag for unambiguous identification,
• lamp information: part number, serial number, production date, ignitions, burn time
• cell information: part number, serial number, production date, nominal path length, volume, maximum pressure
• built-in electronic temperature control (ETC) for improved baseline stability
• built-in holmium oxide filter for fast wavelength accuracy verification.
G1364E Agilent 1260 Infinity II Preparative Fraction Collector
Purification efficiency
• Lowest delay volumes for minimum peak dispersion and carryover
• Automated delay calibration facilitates highest fraction purity while maintaining high-precision sample recovery Instrument efficiency
• Per module collection of up to 216 fractions in glass tubes with 4 outer diameters of tubes available, or in microtiter plates
• Multiple collection modes with fraction triggering based on time, peak, or mass for exact collection of required fractions
Laboratory efficiency
• Expandable capacity up to 864 fractions within the same footprint
• Smooth upgrade paths allow you to increase capacity based on demand
• Forced fume extraction enables use of fraction collector outside a fume cupboard
设备使用相关说明
提供HPLC级别甲醇,乙腈,异丙醇和超纯水,特殊试剂需自备。
HPLC-grade methanol, acetonitrile, isopropanol and ultrapure water are provided, special reagents need to be self-prepared.
凡涉及安全风险的样品(如生物危害、危险化学品、人体来源样品、纳米材料、放射性材料等)须通过生物科学中央实验室准入审查;未通过审查不得入内。相关合规义务及由此产生的责任由本人及所属机构自行承担。
Any samples involving safety risks (such as biohazards, hazardous chemicals, human-derived samples, nanomaterials, or radioactive materials) must pass the BioCRF's access review; samples that do not pass the review may not be brought into the BioCRF. Compliance obligations and any resulting liabilities shall be borne by me and my affiliated institution.
HPLC-grade methanol, acetonitrile, isopropanol and ultrapure water are provided, special reagents need to be self-prepared.
凡涉及安全风险的样品(如生物危害、危险化学品、人体来源样品、纳米材料、放射性材料等)须通过生物科学中央实验室准入审查;未通过审查不得入内。相关合规义务及由此产生的责任由本人及所属机构自行承担。
Any samples involving safety risks (such as biohazards, hazardous chemicals, human-derived samples, nanomaterials, or radioactive materials) must pass the BioCRF's access review; samples that do not pass the review may not be brought into the BioCRF. Compliance obligations and any resulting liabilities shall be borne by me and my affiliated institution.
预约资源
附件下载
公告
同类仪器